Pressure-isolated microneedles for ambulatory hormonal and metabolic monitoring


  • Güntner, A. T. et al. Challenges and alternatives of wearable molecular sensors in endocrinology and metabolism. Nat. Rev. Endocrinol. 22, 50–60 (2026).

    Article 
    PubMed 

    Google Scholar
     

  • Mawe, G. M. & Hoffman, J. M. Serotonin signalling within the intestine—features, dysfunctions and therapeutic targets. Nat. Rev. Gastroenterol. Hepatol. 10, 473–486 (2013).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Spohn, S. N. & Mawe, G. M. Non-conventional options of peripheral serotonin signalling—the intestine and past. Nat. Rev. Gastroenterol. Hepatol. 14, 412–420 (2017).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, Okay., Wang, J. & Gao, W. Wearable chemical sensors for biomarker discovery within the omics period. Nat. Rev. Chem. 6, 899–915 (2022).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Brasier, N. et al. Utilized body-fluid evaluation by wearable gadgets. Nature 636, 57–68 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Heng, W. et al. A wise masks for exhaled breath condensate harvesting and evaluation. Science 385, 954–961 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Zhang, B. et al. A 3-dimensional liquid diode for delicate, built-in permeable electronics. Nature 628, 84–92 (2024).

    Article 
    PubMed 

    Google Scholar
     

  • Shi, J. et al. Lively biointegrated dwelling electronics for managing irritation. Science 384, 1023–1030 (2024).

    Article 
    PubMed 

    Google Scholar
     

  • Lee, H. et al. A graphene-based electrochemical machine with thermoresponsive microneedles for diabetes monitoring and remedy. Nat. Nanotechnol. 11, 566–572 (2016).

    Article 
    PubMed 

    Google Scholar
     

  • Xu, Y. et al. Part-separated porous nanocomposite with ultralow percolation threshold for wi-fi bioelectronics. Nat. Nanotechnol. 19, 1158–1167 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Kim, J. et al. A delicate and clear contact lens for the wi-fi quantitative monitoring of intraocular strain. Nat. Biomed. Eng. 5, 772–782 (2021).

    Article 
    PubMed 

    Google Scholar
     

  • Cho, S. et al. Wearable lateral circulate assays for cortisol monitoring with time-dynamic sweat sampling and sensing by electrochromic timers. Nat. Sens. 1, 85–98 (2026).

    Article 

    Google Scholar
     

  • Kwon, S. et al. At-home wi-fi sleep monitoring patches for the medical evaluation of sleep high quality and sleep apnea. Sci. Adv. 9, eadg9671 (2023).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Friedel, M. et al. Alternatives and challenges within the diagnostic utility of dermal interstitial fluid. Nat. Biomed. Eng. 7, 1541–1555 (2023).

    Article 
    PubMed 

    Google Scholar
     

  • Vora, L. Okay. et al. Microneedle-based biosensing. Nat. Rev. Bioeng. 2, 64–81 (2024).

    Article 

    Google Scholar
     

  • Lee, W. et al. Conformable microneedle pH sensors by way of the mixing of two totally different siloxane polymers for mapping peripheral artery illness. Sci. Adv. 7, eabi6290 (2021).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Yang, J. et al. Masticatory system–impressed microneedle theranostic platform for clever and exact diabetic administration. Sci. Adv. 8, eabo6900 (2022).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Zheng, Y. et al. A wearable microneedle-based prolonged gate transistor for real-time detection of sodium in interstitial fluids. Adv. Mater. 34, 2108607 (2022).

    Article 

    Google Scholar
     

  • Bai, J. et al. Coin-sized, absolutely built-in, and minimally invasive steady glucose monitoring system based mostly on natural electrochemical transistors. Sci. Adv. 10, eadl1856 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Ausri, I. R. et al. Multifunctional dopamine-based hydrogel microneedle electrode for steady ketone sensing. Adv. Mater. 36, 2402009 (2024).

    Article 

    Google Scholar
     

  • Ashraf, G. et al. Microneedle-integrated FePc–MOF–MXene nanozyme patch for in vivo L-cysteine monitoring. Adv. Mater. 37, 2502804 (2025).

    Article 

    Google Scholar
     

  • Wu, Y. et al. Microneedle aptamer-based sensors for steady, real-time therapeutic drug monitoring. Anal. Chem. 94, 8335–8345 (2022).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Lin, S. et al. Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of medicine with slim therapeutic home windows. Sci. Adv. 8, eabq4539 (2022).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Yang, J. et al. Microneedle-based built-in pharmacokinetic and pharmacodynamic analysis platform for customized medication. Nat. Commun. 16, 6260 (2025).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Sales space, M. A. et al. Pilot section medical trial of a wearable, electrochemical aptamer-based patch for steady drug focus measurement. Nat. Biotechnol. https://doi.org/10.1038/s41587-026-03010-w (2026).

  • GhavamiNejad, A. et al. Steady insulin monitoring utilizing an antibody-protecting zwitterionic microneedle patch. Nat. Biomed. Eng. https://doi.org/10.1038/s41551-025-01477-7 (2025).

  • Al Sulaiman, D. et al. Hydrogel-coated microneedle arrays for minimally invasive sampling and sensing of particular circulating nucleic acids from pores and skin interstitial fluid. ACS Nano 13, 9620–9628 (2019).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Yang, B., Kong, J. & Fang, X. Programmable CRISPR-Cas9 microneedle patch for long-term seize and real-time monitoring of common cell-free DNA. Nat. Commun. 13, 3999 (2022).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Wang, Z. et al. Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid. Nat. Biomed. Eng. 5, 64–76 (2021).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Zargartalebi, H. et al. Lively-reset protein sensors allow steady in vivo monitoring of irritation. Science 386, 1146–1153 (2024).

    Article 
    PubMed 

    Google Scholar
     

  • Lin, Z.-T. et al. Wearable photonic machine for a number of biomarker sampling and detection with out blood attracts. Adv. Mater. 37, 2416240 (2025).

    Article 

    Google Scholar
     

  • Tehrani, F. et al. An built-in wearable microneedle array for the continual monitoring of a number of biomarkers in interstitial fluid. Nat. Biomed. Eng. 6, 1214–1224 (2022).

    Article 
    PubMed 

    Google Scholar
     

  • Zhu, B. et al. A wearable built-in microneedle electrode patch for train administration in diabetes. Analysis 7, 0508 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Chang, A.-Y. et al. Integration of chemical and bodily inputs for monitoring metabolites and cardiac alerts in diabetes. Nat. Biomed. Eng. 10, 94–109 https://doi.org/10.1038/s41551-025-01439-z (2025).

  • Gill, H. S., Denson, D. D., Burris, B. A. & Prausnitz, M. R. Impact of microneedle design on ache in human volunteers. Clin. J. Ache 24, 585–594 (2008).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Makvandi, P. et al. Engineering microneedle patches for improved penetration: evaluation, pores and skin fashions and components affecting needle insertion. Nano-Micro Lett. 13, 93 (2021).

    Article 

    Google Scholar
     

  • Kim, G., Ahn, H., Chaj Ulloa, J. & Gao, W. Microneedle sensors for dermal interstitial fluid evaluation. Med-X 2, 15 (2024).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Römgens, A. M., Bader, D. L., Bouwstra, J. A., Baaijens, F. P. T. & Oomens, C. W. J. Monitoring the penetration strategy of single microneedles with various tip diameters. J. Mech. Behav. Biomed. Mater. 40, 397–405 (2014).

    Article 
    PubMed 

    Google Scholar
     

  • Kang, J. et al. A conformable microneedle sensor with photopatternable pores and skin adhesive and gel electrolyte for steady glucose monitoring. Machine 1, 100112 (2023).

    Article 

    Google Scholar
     

  • Reynoso, M. et al. 3D-printed, aptamer-based microneedle sensor arrays utilizing magnetic placement on stay rats for pharmacokinetic measurements in interstitial fluid. Biosens. Bioelectron. 244, 115802 (2024).

    Article 
    PubMed 

    Google Scholar
     

  • Yabut, J. M. et al. Rising roles for serotonin in regulating metabolism: new implications for an historical molecule. Endocr. Rev. 40, 1092–1107 (2019).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Faraji Rad, Z., Prewett, P. D. & Davies, G. J. Excessive-resolution two-photon polymerization: probably the most versatile approach for the fabrication of microneedle arrays. Microsyst. Nanoeng. 7, 1–17 (2021).

    Article 

    Google Scholar
     

  • Dervisevic, M., Harberts, J., Sánchez-Salcedo, R. & Voelcker, N. H. 3D Polymeric lattice microstructure-based microneedle array for transdermal electrochemical biosensing. Adv. Mater. 36, 2412999 (2024).

    Article 

    Google Scholar
     

  • Azarikhah, P. et al. A important evaluate of advances and challenges in microinjection moulding of polymeric microneedles. J. Drug Deliv. Sci. Technol. 114, 107435 (2025).

    Article 

    Google Scholar
     

  • Koelmans, W. et al. Microneedle characterization utilizing a double-layer pores and skin simulant. Mech. Eng. Res. 3, p51 (2013).

    Article 

    Google Scholar
     

  • Nakatsuka, N. et al. Aptamer–field-effect transistors overcome Debye size limitations for small-molecule sensing. Science 362, 319–324 (2018).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Min, J. et al. Steady biochemical profiling of the gastrointestinal tract utilizing an built-in good capsule. Nat. Electron. 8, 844–855 (2025).

    Article 

    Google Scholar
     

  • Ferguson, B. S. et al. Actual-time, aptamer-based monitoring of circulating therapeutic brokers in dwelling animals. Sci. Transl. Med. 5, 213ra165 (2013).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Vaidya, R., Atanasov, P. & Wilkins, E. Impact of interference on the efficiency of glucose enzyme electrodes utilizing Nafion® coatings. Med. Eng. Phys. 17, 416–424 (1995).

    Article 
    PubMed 

    Google Scholar
     

  • Barradas, M. A., Gill, D. S., Fonseca, V. A., Mikhailidis, D. P. & Dandona, P. Intraplatelet serotonin in sufferers with diabetes mellitus and peripheral vascular illness. Eur. J. Clin. Make investments. 18, 399–404 (1988).

    Article 
    PubMed 

    Google Scholar
     

  • Younger, R. L. et al. Augmented capability for peripheral serotonin launch in human weight problems. Int. J. Obes. 42, 1880–1889 (2018).

    Article 

    Google Scholar
     

  • Malyszko, J., Urano, T., Takada, Y. & Takada, A. Stress-dependent modifications in fibrinolysis, serotonin and platelet aggregation in rats. Life Sci. 54, 1275–1280 (1994).

    Article 
    PubMed 

    Google Scholar
     

  • Takada, Y., Ihara, H., Urano, T. & Takada, A. Adjustments in blood and plasma serotonergic measurements in rats—impact of nicotine and/or publicity to totally different stresses. Thromb. Res. 80, 307–316 (1995).

    Article 
    PubMed 

    Google Scholar
     

  • Teradaira, R. et al. Psychological stress-induced modifications in plasma serotonin, tryptophan, kynurenine concentrations in wholesome individuals. Int. Congr. Ser. 1304, 175–179 (2007).

    Article 

    Google Scholar
     

  • Lyte, J. M. et al. Intestine–mind axis serotonergic responses to acute stress publicity are microbiome-dependent. Neurogastroenterol. Motil. 32, e13881 (2020).

    Article 
    PubMed 

    Google Scholar
     

  • Van Cromphaut, S. J. Hyperglycaemia as a part of the stress response: the underlying mechanisms. Greatest Pract. Res. Clin. Anaesthesiol. 23, 375–386 (2009).

    Article 
    PubMed 

    Google Scholar
     

  • Rebrin, Okay. et al. Subcutaneous glucose monitoring via electrochemical sensors: fiction or actuality? J. Biomed. Eng. 14, 33 (1992).

    Article 
    PubMed 

    Google Scholar
     

  • Moatti-Sirat, D. et al. In the direction of steady glucose monitoring: in vivo analysis of a miniaturized glucose sensor implanted for a number of days in rat subcutaneous tissue. Diabetologia 35, 224–230 (1992).

    Article 
    PubMed 

    Google Scholar
     

  • Wisniewski, N. & Reichert, M. Strategies for decreasing biosensor membrane biofouling. Colloids Surf. B Biointerfaces 18, 197–219 (2000).

    Article 
    PubMed 

    Google Scholar
     

  • Leung, Okay. Okay., Downs, A. M., Ortega, G., Kurnik, M. & Plaxco, Okay. W. Elucidating the mechanisms underlying the sign drift of electrochemical aptamer-based sensors in complete blood. ACS Sens. 6, 3340–3347 (2021).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Yamada, J., Sugimoto, Y., Kimura, I., Takeuchi, N. & Horisaka, Okay. Serotonin-induced hypoglycemia and elevated serum insulin ranges in mice. Life Sci. 45, 1931–1936 (1989).

    Article 
    PubMed 

    Google Scholar
     

  • Sumara, G., Sumara, O., Kim, J. Okay. & Karsenty, G. Intestine-derived serotonin is a multifunctional determinant to fasting adaptation. Cell Metab. 16, 588–600 (2012).

    Article 
    PubMed 
    PubMed Central 

    Google Scholar
     

  • Audhya, T., Adams, J. B. & Johansen, L. Correlation of serotonin ranges in CSF, platelets, plasma, and urine. Biochim. Biophys. Acta Gen. Subj. 1820, 1496–1501 (2012).

    Article 

    Google Scholar
     

  • Levine, S. P. et al. Platelet activation and secretion related to emotional stress. Circulation 71, 1129–1134 (1985).

    Article 
    PubMed 

    Google Scholar
     

  • Sánchez, S. et al. Circadian variations of serotonin in plasma and totally different mind areas of rats. Mol. Cell. Biochem. 317, 105–111 (2008).

    Article 
    PubMed 

    Google Scholar
     

  • Deixe um comentário